Division |
Main ingredient |
M.P ( ℃ ) |
Working temperature( ℃ ) |
Characteristics and temperature |
Fluoride system Flux |
K. AI. F |
560~575 |
580~630 |
- Fluoride system does not require cleaning after brazing - Excellent anti-corrosive coating on Flux surface - Brazing can be done in small quantity and continuous mass production is possible. - AI surface when Brazing of automobile air conditioner to NB of parts An oxide film removing agent |
Chloride system Flux |
Li, Zn, CI K, Na, F |
380~500 |
450~590 |
- It is used for torch welding due to low working temperature. - Cleaning and fixing of CI component after work is required |
Low M.P Flux |
K, AI, F, Cs |
400~500 |
450~550 |
- Fluoride system and low working temperature. - No need for further washing process after work, nor for coating Flux - Corrosion protection function |
| Packaging and dimensions
◊ 15kg, Solvay Flux bag (fluoride system)
◊ 1kg, Toyo-metal plastic container (chloride system)